CHU-8-OPEN-PAR
CHU8 P3039M 6AR
MCP39PAR30LN/U/830/FL/ECO LAMP, 0.4 S/MH, 2300 RATED LUMENS, TEST NO. LTL19285
CHU8 P3070M 6AR
CDM70/830/PAR30L/MFL LAMP, 0.6 S/MH, 5000 RATED LUMENS, TEST NO. LTL19284
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
8” CHU
Up/Down, Wall-Mounted Cylinder
PAR Metal Halide, 6” Aperture
CHU8 P3870M 6AR
CDM70/PAR38/WFL LAMP, 0.7 S/MH, 3700 RATED LUMENS, TEST NO. LTL19286
20° 40°
60°
80°
100°
120°
140° 160°180°
420
0
840
0
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
10634
8906
3226
467
140
98
4
1
0
1
1
759
891
246
91
69
10
1
0
1
Zone Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 120°
90° - 130°
90° - 150°
90° - 180°
0° - 180°
1897.0
1987.8
2067.0
2068.9
3.6
9.7
154.1
1848.1
3917.1
41.2
43.2
44.9
45.0
0.1
0.2
3.4
40.2
*85.2
*Efficiency
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
92
84
77
72
67
62
59
56
53
50
48
92
82
74
67
62
58
54
51
48
46
44
92
80
71
64
58
54
50
47
45
43
41
85
78
72
67
63
59
56
53
51
48
46
85
76
69
64
59
55
52
49
46
44
42
85
75
67
61
56
52
49
46
44
42
40
72
67
63
59
56
53
51
48
46
45
43
72
66
61
57
53
50
48
45
43
42
40
72
65
59
55
51
48
45
43
41
39
38
RCR
50% beam -
22.0°
10% beam -
39.9°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
351.5
189.0
117.8
80.4
58.3
2.1
2.9
3.7
4.5
5.2
175.8
94.6
58.9
40.2
29.2
4.0
5.4
6.9
8.3
9.8
35.1
18.9
11.8
8.0
5.8
20° 40°
60°
80°
100°
120°
140° 160°180°
4400
8800
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
11333
10924
7861
2119
407
181
23
3
1
1
0
1003
2083
1051
283
135
36
3
1
1
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 120°
90° - 130°
90° - 150°
90° - 180°
0° - 180°
4137.1
4419.8
4591.0
4595.3
9.1
29.5
376.3
4058.6
8653.8
41.4
44.2
45.9
46.0
0.1
0.3
3.8
40.6
*86.5
*Efficiency
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
93
85
78
72
67
62
58
54
51
48
46
93
83
74
67
62
57
53
49
46
43
41
93
80
71
64
58
53
49
46
43
40
38
86
79
73
68
63
59
55
52
49
46
44
86
77
70
64
59
54
51
47
45
42
40
86
75
67
61
55
51
47
44
41
39
37
74
68
64
60
56
53
50
47
45
43
41
74
67
61
57
53
49
46
44
41
39
37
74
66
59
54
50
47
44
41
39
37
35
RCR
50% beam -
34.6°
10% beam -
53.4°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
374.6
201.5
125.6
85.7
62.2
3.4
4.7
5.9
7.2
8.4
187.3
100.8
62.8
42.9
31.1
5.5
7.6
9.6
11.6
13.6
37.5
20.2
12.6
8.6
6.2
20° 40°
60°
80°
100°
120°
140° 160°180°
1800
3600
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
4500
4305
3201
1565
370
19
4
1
0
0
0
401
874
709
249
20
4
1
0
0
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 120°
90° - 130°
90° - 150°
90° - 180°
0° - 180°
1983.4
2232.5
2256.4
2258.3
5.6
11.7
189.3
1810.9
4069.2
26.8
30.2
30.5
30.5
0.1
0.2
2.6
24.5
*55.0
*Efficiency
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
60
54
50
46
42
39
37
34
32
31
29
60
53
47
43
39
36
33
31
29
27
26
60
51
45
41
37
34
31
29
27
25
24
55
51
47
43
40
37
35
33
31
29
28
55
49
45
41
37
35
32
30
28
26
25
55
48
43
39
35
32
30
28
26
24
23
48
44
41
38
36
34
32
30
28
27
26
48
43
40
37
34
32
30
28
26
25
23
48
42
38
35
32
30
28
26
25
23
22
RCR
50% beam -
36.2°
10% beam -
62.9°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
148.8
80.0
49.9
34.0
24.7
3.6
4.9
6.2
7.5
8.8
74.4
40.0
24.9
17.0
12.3
6.7
9.2
11.6
14.1
16.5
14.9
8.0
5.0
3.4
2.5
PHOTOMETRY NOTES
Tested to current IES and NEMA standards under stabilized laboratory conditions.
Actual performance may differ as a result of end-user environment and application.