GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2012-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/18/13. Specifications subject to change without notice.
PAGE 3 OF 3
VRAPR-6-LENSED
PHOTOMETRY
6” VRAPR
Lightshield™
PAR30 or PAR38 Lamp
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
VRAPR PAR38 6AR T73
(1) 90W PAR38 LAMP, 1470 RATED LUMENS, 0.8 S/MH TEST NO. LTL20594
VRAPR PAR38 6AR CGL
(1) 90W PAR38 LAMP, 1470 RATED LUMENS, 0.3 S/MH TEST NO. LTL20595
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
40°
60°
80°
600
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
1478
1500
1441
451
76
20
9
5
2
0
0
145
379
219
53
17
8
5
2
0
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
743.0
795.9
820.7
828.1
0.0
828.1
50.5
54.1
55.8
56.3
0.0
*56.3
*Efficiency
pc 80%70% 50%
pw 50%30% 10%50% 30%10% 50%30% 10%
0
1
2
3
4
5
6
7
8
9
10
67
63
59
56
53
51
48
46
44
42
41
67
62
57
54
51
48
46
43
41
40
38
67
61
56
52
49
46
43
41
39
38
36
66
62
58
55
53
50
48
46
44
42
40
66
61
57
53
50
48
45
43
41
39
38
66
60
55
51
48
46
43
41
39
38
36
63
60
57
54
51
49
47
45
43
42
40
63
59
55
52
49
47
45
43
41
39
38
63
58
54
51
48
45
43
41
39
38
36
RCR
50% beam -
41.3°
10% beam -
57.9°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
48.9
26.3
16.4
11.2
8.1
4.1
5.7
7.2
8.7
10.2
24.4
13.1
8.2
5.6
4.1
6.1
8.3
10.5
12.7
14.9
4.9
2.6
1.6
1.1
0.8
40°
60°
80°
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
9438
6701
767
109
15
3
1
1
0
0
0
499
251
56
11
3
1
1
0
0
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
805.4
816.6
820.7
821.8
0.0
821.8
54.8
55.6
55.8
55.9
0.0
*55.9
*Efficiency
pc 80%70% 50%
pw 50%30% 10%50% 30%10% 50%30% 10%
0
1
2
3
4
5
6
7
8
9
10
67
64
61
59
58
56
55
54
53
52
51
67
63
60
58
56
54
53
52
51
50
49
67
62
59
56
55
53
52
51
50
49
48
65
63
60
59
57
56
55
54
53
52
51
65
62
59
57
55
54
53
52
51
50
49
65
61
58
56
54
53
52
51
50
49
48
62
60
59
57
56
55
54
53
52
51
51
62
60
58
56
55
54
52
51
51
50
49
62
59
57
55
54
52
51
50
50
49
48
RCR
50% beam -
14.3°
10% beam -
27.9°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
312.0
167.8
104.6
71.4
51.8
1.4
1.9
2.4
2.9
3.4
156.1
83.9
52.3
35.7
25.9
2.7
3.7
4.7
5.7
6.7
31.2
16.8
10.4
7.1
5.2
Kommentare zu diesen Handbüchern