GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2003-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/19/13. Specifications subject to change without notice.
PAGE 3 OF 4
CF11-8-OPEN
CF11 1/32TRT 8AR
(1) 32W CF32DT/E/IN/835 LAMP, 1.2 S/MH, 2400 RATED LUMENS PER LAMP, TEST NO. LTL9452
CF11 1/42TRT 8AR
(1) 42W CF42DT/E/IN/835 LAMP, 1.3 S/MH, 3200 RATED LUMENS PER LAMP, TEST NO. LTL9455
CF11 2/18DTT 8AR
(2) 18W CF18DD/E/827 LAMPS, 1.3 S/MH, 1250 RATED LUMENS PER LAMP, TEST NO. 2196080601
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
11” CF
Cylinders
Horizontal Lamp, Double Twin-Tube or Triple-Tube, 8” Aperture
40°
60°
80°
0
0
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
1005
1005
961
917
635
592
41
11
9
8
0
95
275
416
405
354
46
11
10
8
Zone Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
785.7
1190.3
1590.4
1619.7
0.0
1619.7
32.7
49.6
66.3
67.5
0.0
*67.5
*Efficiency
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
80
74
67
62
56
52
48
44
41
38
35
80
72
64
57
52
47
43
39
36
33
31
80
70
61
54
49
44
39
36
33
30
28
78
72
66
61
56
51
47
43
40
37
35
78
70
63
57
51
47
43
39
36
33
30
78
69
61
54
48
43
39
36
33
30
28
75
69
64
59
54
50
46
43
39
37
34
75
68
61
56
50
46
42
38
35
33
30
75
67
59
53
48
43
39
35
32
30
27
RCR
50% beam -
60.9°
10% beam -
94.7°
Mounting
Height
Inital FC
Center
Beam DiameterFC DiameterFC
8.0
10.0
12.0
14.0
16.0
33.2
17.9
11.1
7.6
5.5
6.5
8.8
11.2
13.5
15.9
16.6
8.9
5.6
3.8
2.8
11.9
16.3
20.6
25.0
29.3
3.3
1.8
1.1
0.8
0.6
40°
60°
80°
400
800
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
1295
1285
1325
1296
905
785
39
4
1
0
0
122
373
588
570
464
49
4
1
0
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1083.2
1653.4
2166.3
2171.7
0.0
2171.7
33.8
51.7
67.7
67.9
0.0
*67.9
*Efficiency
pc 80% 70% 50%
pw 50% 30% 10%50% 30% 10% 50%30% 10%
0
1
2
3
4
5
6
7
8
9
10
81
74
68
62
57
53
49
45
41
38
36
81
72
65
59
53
48
44
40
37
34
31
81
71
62
55
50
45
40
37
34
31
28
79
73
67
61
56
52
48
44
41
38
36
79
71
64
58
52
48
43
40
37
34
31
79
70
62
55
49
44
40
37
33
31
28
75
70
65
60
55
51
47
43
40
37
35
75
69
62
57
51
47
43
39
36
33
31
75
67
60
54
49
44
40
36
33
31
28
RCR
50% beam -
64.4°
10% beam -
94.8°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
42.8
23.0
14.3
9.8
7.1
6.9
9.5
12.0
14.5
17.0
21.4
11.5
7.2
4.9
3.6
12.0
16.3
20.7
25.0
29.3
4.3
2.3
1.4
1.0
0.7
40°
60°
80°
0
0
0
0
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
811
841
864
827
654
122
6
0
0
0
0
81
245
377
380
109
6
0
0
0
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
702.5
1082.4
1198.0
1198.0
0.0
1198.0
28.1
43.3
47.9
47.9
0.0
*47.9
*Efficiency
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
57
53
49
45
42
39
36
34
31
29
27
57
52
47
43
39
36
33
30
28
26
24
57
50
45
41
37
34
31
28
26
24
22
56
52
48
44
41
38
36
33
31
29
27
56
51
46
42
39
36
33
30
28
26
24
56
50
45
40
37
33
31
28
26
24
22
53
50
46
43
40
37
35
33
30
28
27
53
49
45
41
38
35
32
30
28
26
24
53
48
44
40
36
33
30
28
26
24
22
RCR
50% beam -
66.9°
10% beam -
85.5°
Mounting
Height
Inital FC
Center
Beam DiameterFC DiameterFC
8.0
10.0
12.0
14.0
16.0
26.8
14.4
9.0
6.1
4.4
7.3
9.9
12.5
15.2
17.8
13.4
7.2
4.5
3.1
2.2
10.2
13.9
17.6
21.3
25.0
2.7
1.4
0.9
0.6
0.4
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.